{"product_id":"pentair-eti-250-propane-conversion-kit-heaters-below-2000-feet-476370","title":"Pentair Propane Conversion Orifices | ETi 250 Pool Heater | 476370","description":"\u003cp\u003eThe Pentair Propane Conversion Orifices (476370) is the OEM replacement propane conversion kit for the Pentair ETi 250 High-Efficiency Pool \u0026amp; Spa Heater, enabling a natural gas unit to operate on liquid propane (LP) fuel at elevations from 0 to 2,000 feet (0–610 meters).\u003c\/p\u003e\n\n\u003cp style=\"background-color: #fff3cd; border: 2px solid #FFEAA7; padding: 15px; border-radius: 5px; margin: 15px 0; color: #856404;\"\u003e\u003cstrong\u003eIMPORTANT: ALTITUDE RESTRICTION — DO NOT INSTALL ABOVE 2,000 FEET \/ 610 METERS\u003c\/strong\u003e\u003cbr\u003eThis kit is rated for heaters installed at elevations between 0 and 2,000 feet (610 meters) only. Installing this kit in a heater located above 2,000 feet will result in incorrect fuel-to-air ratios and unsafe operation. A separate high-altitude propane conversion kit is required for installations above this elevation. Verify your site elevation before ordering.\u003c\/p\u003e\n\n\u003cp style=\"background-color: #fff3cd; border: 2px solid #FFEAA7; padding: 15px; border-radius: 5px; margin: 15px 0; color: #856404;\"\u003e\u003cstrong\u003eIMPORTANT: THIS LISTING IS FOR A KIT — MULTIPLE COMPONENTS INCLUDED\u003c\/strong\u003e\u003cbr\u003eThis kit contains the orifice components required to convert the ETi 250 from natural gas to liquid propane. Confirm that all kit contents are present before beginning the conversion. Professional installation is required.\u003c\/p\u003e\n\n\u003cp style=\"background-color: #fff3cd; border: 2px solid #FFEAA7; padding: 15px; border-radius: 5px; margin: 15px 0; color: #856404;\"\u003e\u003cstrong\u003eIMPORTANT: LICENSED PROFESSIONAL INSTALLATION REQUIRED — GAS APPLIANCE CONVERSION\u003c\/strong\u003e\u003cbr\u003eGas and electrical heater components must be serviced by a licensed pool professional or qualified HVAC technician. Do not attempt to service gas or high-voltage components without proper certification. A carbon monoxide (CO) detector should be installed in any enclosed or semi-enclosed area where this heater operates.\u003c\/p\u003e\n\n\u003cp\u003eThis kit supplies the correct LP orifices needed to reconfigure the ETi 250 burner assembly for propane fuel delivery. Natural gas and propane operate at different pressures and require different orifice sizing; installing the correct orifices ensures the heater maintains rated combustion efficiency and safe operation on LP. Without the properly sized orifices, the heater will run rich or lean, producing incomplete combustion, reduced output, and potential safety hazards.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0; border: 1px solid #ccc;\"\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003ePentair Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e476370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003ePart Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePropane Conversion Orifices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003ePart Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eGas Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eQuantity Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eKit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eFuel Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eNatural Gas (NG) to Liquid Propane (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eAltitude Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e0 to 2,000 feet (0–610 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003ePackaged Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e8L × 8W × 8H inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003ePackaged Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFits Into\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0; border: 1px solid #ccc;\"\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eEquipment Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePentair\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eETi 250 High-Efficiency Pool Heater\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e461112\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePropane Conversion Kit from 0–2,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePentair\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eETi 250\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eETi-250\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eRefer to ETi 250 Propane Conversion Kit installation guide to determine suitability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePentair\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eETi 250\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eETi250\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eRefer to ETi 250 Propane Conversion Kit installation guide to determine suitability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eCompatibility is based on Pentair parts documentation and available OEM records. This is not an exhaustive list. For certainty, verify the part number in your equipment's manual or on the original part itself before ordering.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003ePoolaroo Pro Tip\u003c\/h3\u003e\n\u003cp\u003eBefore ordering, confirm your installation site elevation. The 476370 kit is calibrated for LP combustion at sea level through 2,000 feet — the orifice sizing is not interchangeable with high-altitude variants. If you are close to the 2,000-foot threshold, measure your actual site elevation rather than estimating by zip code or nearest city. After the conversion is complete, a licensed technician should verify manifold pressure and perform a combustion analysis to confirm the heater is operating within the ETi 250's rated parameters.\u003c\/p\u003e\n\n\u003c!-- wft:processed:manual:2026-05-01 --\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":52770077802771,"sku":"476370","price":48.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/poolaroo.com\/products\/pentair-eti-250-propane-conversion-kit-heaters-below-2000-feet-476370","provider":"Poolaroo","version":"1.0","type":"link"}