{"product_id":"pentair-intelliph-size-c-pump-tube-522480","title":"Pentair Pump Tubes for Tank Mounted Pump | IntelliChem \u0026 IntellipH | 522480","description":"\u003cp\u003eThe Pentair Pump Tubes for Tank Mounted Pump (522480) are the OEM replacement peristaltic pump tubes for the IntelliChem Chemical Controller and IntellipH Chemical Dosing systems — sold in a pack of two.\u003c\/p\u003e\n\n\u003cp\u003eThese flexible pump tubes are the consumable wear component inside the tank-mounted peristaltic dosing pump. The tube's repeated compression and release as the pump head rotates delivers precise chemical volumes — making tube condition directly responsible for accurate dosing. As the tube material fatigues, it loses elasticity, which causes inconsistent chemical delivery and can eventually allow tubing failure and chemical leaks. Replacing on schedule keeps your chemical controller operating with the precision it was calibrated for.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0; border: 1px solid #ccc;\"\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003ePentair Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e522480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003ePart Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePump Tubes for Tank Mounted Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eQuantity Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePack of 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eIntelliChem Chemical Controller (Tank Mounted Pump); IntellipH Chemical Container\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFits Into\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0; border: 1px solid #ccc;\"\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eEquipment Line\u003c\/strong\u003e\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePentair\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eIntelliChem\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eINTELLICHEM\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eFor Tank Mounted Pump; recommend replacing every 6 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePentair\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eIntellipH\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e522712\u003c\/td\u003e\n  \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003ePump Tubes for Tank Mounted Pump — Chemical Container replacement part. Verify fitment before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eCompatibility is based on Pentair parts documentation and available OEM records. This is not an exhaustive list. For certainty, verify the part number in your equipment's manual or on the original part itself before ordering.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003ePoolaroo Pro Tip\u003c\/h3\u003e\n\u003cp\u003ePentair recommends replacing these pump tubes every 6 months regardless of visible wear. Peristaltic tube degradation is internal — the tube wall thins and loses elasticity before any outward signs of failure appear. Scheduling replacement at the start and midpoint of your pool season is the simplest way to maintain dosing accuracy and avoid unexpected chemical feed interruptions. A pack of two gives you both spares on hand for a full year of scheduled maintenance.\u003c\/p\u003e\n\n\u003c!-- wft:processed:manual:2026-05-01 --\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":51774184620307,"sku":"522480","price":63.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0920\/0687\/5411\/files\/PEN522480_0.jpg?v=1747702974","url":"https:\/\/poolaroo.com\/products\/pentair-intelliph-size-c-pump-tube-522480","provider":"Poolaroo","version":"1.0","type":"link"}